Knowledge Base · Florida Climate & Code

How Wind-Rated Is a Metal Roof for Florida Hurricanes?

In Florida a metal roof is not rated by a single mph number. Florida Product Approval NEMO P.E. Evaluated FL7263-R7 documents Interlock aluminum shingle, slate, shake and tile profiles at design pressures from −30 to −187.5 psf by profile and fastening, tested to UL 1897, UL 580 and TAS 125, outside the HVHZ. The Guardian warranty adds 120 mph when installed to manufacturer specification.

Reviewed by Scott Plumptree, Director of Marketing, The Interlock Group · Updated August 27, 2026

At a glance

  • ASCE 7-22 design wind speeds run about 130–140 mph in Jacksonville and Orlando, 150–160 in Tampa and about 170 in Collier County.
  • NEMO P.E. Evaluated FL7263-R7 lists design pressures of −30 to −187.5 psf by profile and fastening, tested to UL 1897, UL 580 and TAS 125.
  • NEMO P.E. Evaluated FL7263-R7 is non-HVHZ only; Miami-Dade and Broward are not covered and are not served.
  • Standing seam is not listed in NEMO P.E. Evaluated FL7263-R7 and carries no Florida approval under it.
  • The Guardian warranty covers wind to 120 mph when installed to manufacturer specification.

What wind speed does a roof have to be designed for in Florida?

Florida does not use one wind speed. The Florida Building Code 8th Edition (2023), in effect since December 31, 2023, adopted ASCE 7-22, and that standard assigns a design wind speed to every point on the map for a Risk Category II house. For the Panhandle, Jacksonville and Orlando that figure is roughly 130 to 140 mph. Tampa sits at about 150 to 160. Southwest Florida, meaning Collier County and the coast around Naples, is at about 170, and the Keys run 170 to 180 in Exposure D, the open-water exposure that pushes loads higher still. These are not forecast speeds. They are three-second gust values with a return period long enough that a roof designed to them has a small but not zero chance of seeing them in its life. A roof in Orange Park and a roof in Marco Island are designed for different storms, and the fastening schedule for the same metal shingle changes between them. That is the first thing to understand before reading any manufacturer's wind claim. The 9th Edition, effective December 31, 2026, keeps the peninsula largely where it is but raises Panhandle wind speeds. A homeowner in Pensacola or Panama City who permits after that date will be designing to a higher number than a neighbor who permitted this year.

Why is a metal roof rated in pressure rather than miles per hour?

Wind does not pull on a roof by speed. It pulls by pressure, and pressure rises with the square of speed. Going from 130 mph in Orlando to 170 mph in Collier County is a 31 percent increase in speed but roughly a 71 percent increase in uplift pressure. That is why product approvals and engineers work in pounds per square foot rather than mph, and why a roof that is fine on the I-4 corridor may need a denser fastener pattern on the Southwest coast. The pressure is also not uniform across a roof. Wind separating over eaves, rakes, ridges and hips creates suction that is often two to three times higher at the perimeter and corners than in the field of the roof. The engineer's calculation for your address produces a negative design pressure for each of those zones, and the roof covering has to be documented to resist at least that number in each zone. So the honest answer to how many mph a metal roof is rated for is that the roof is rated in psf, the county sets the mph, and someone with a license has to turn one into the other for your house. Any single mph number on a brochure is a warranty figure or a marketing figure, not a code figure.

What does Florida Product Approval NEMO P.E. Evaluated FL7263-R7 actually document?

Florida Product Approval NEMO P.E. Evaluated FL7263-R7 is the state's evaluation of the Interlock aluminum roofing system under the FBC 8th Edition. It covers the Shingle and Slate profiles in nail-strip and nail-tab versions, the Diamond, the Shake, and the Hidden-Fastener Tile, in 0.019 to 0.027 inch aluminum. The system was tested to UL 1897 for uplift, UL 580 for uplift resistance of roof assemblies, and TAS 125, the Florida test protocol for metal roof assemblies. It was evaluated by Robert Nieminen, P.E. of NEMO ETC, with UL LLC as the quality-assurance entity. The approval lists design pressures from −30.0 psf to −187.5 psf. That range is deliberate. The number for your roof depends on the profile, the fastener type and spacing, and the deck it is going into, with a minimum of 15/32 inch plywood and 19/32 inch for some configurations, fastened with ring-shank nails or wood screws. There is no single rating; there is a table, and the installer picks the row that meets or exceeds the design pressure the engineer calculated for your county and roof zone. Two limits need to be said plainly. NEMO P.E. Evaluated FL7263-R7 is a non-HVHZ approval. It does not cover Miami-Dade or Broward County, the High-Velocity Hurricane Zone, and there is no Miami-Dade NOA. This site does not serve those two counties. Monroe County is not HVHZ but sits at 170 to 180 mph in Exposure D and is handled case by case. Standing seam is also not listed in NEMO P.E. Evaluated FL7263-R7, so no Florida approval can be claimed for it under this document.

Why do shingles blow off in a hurricane and interlocking metal does not?

An asphalt shingle is held down by a strip of sealant and a few nails through its upper half. Its bottom edge is free. When a gust separates over the ridge or eave, suction lifts that free edge, the sealant bond breaks, and once one tab lifts the wind has a handle on the next course up. After Irma and Ian the pattern across Fort Myers, Port Charlotte and Punta Gorda was the same: shingle roofs lost the corners and eave courses first, then unzipped. Heat matters too. Sealant that has spent a decade of South Florida summers over 100°F heat index has less bond left than the lab sample. An Interlock aluminum shingle has no free edge. Each panel folds into the panel above, below and on both sides in a four-way interlock, and the fasteners sit under the interlock where they are protected. Wind cannot get a fingerhold on a single panel because the panel is mechanically tied to its neighbors on all four sides. Uplift is spread across the interlocking field and down through the fasteners into the deck rather than concentrated on one exposed edge. That is also why the deck and underlayment matter as much as the panel. The FBC steep-slope rules in R905.1.1 require either a full-deck self-adhered ASTM D1970 membrane, self-adhered strips over the joints plus underlayment, or a two-ply felt system with cap nails, with metal caps where the design wind is 170 mph or higher. Section 553.844 adds deck re-nailing and a secondary water barrier at reroof. A metal roof rated to −187.5 psf on a deck nailed to a 1975 schedule is rated to whatever that deck can hold.

What does the warranty cover, and what should I get from the installer in writing?

The Guardian Lifetime Limited Material Warranty carries a warranted wind resistance of 120 mph when installed to manufacturer specification. Those two clauses go together. The 120 mph figure is a warranty commitment, not the code rating, and it applies only when the fastening and underlayment match the manufacturer's specification, which in Florida means the NEMO P.E. Evaluated FL7263-R7 configuration chosen for your design pressure. Metal Roofing Florida does not install; a certified Interlock installer is assigned to your project and pulls the permit under their own license. There is no Florida installation history to point to here, so the documents are what you rely on. Ask the assigned installer for four things before the first panel goes on. First, the NEMO P.E. Evaluated FL7263-R7 approval number on the permit application, with the specific profile and fastening row selected and the design pressure it covers for your county. Second, the engineer's or code official's design pressures for field, perimeter and corner zones so you can see the row exceeds them. Third, the underlayment method under R905.1.1 and the §553.844 deck re-nailing and secondary water barrier, written on the permit scope. Fourth, on completion, a signed OIR-B1-1802 mitigation inspection. That last form is where the insurance side lives. The 1802 records roof covering, deck attachment, roof-to-wall attachment, roof geometry and secondary water resistance, and insurers must offer mitigation discounts under §627.0629, but a new metal roof does not earn a credit by itself. The credit follows what the inspection documents, so ask your carrier what each line is worth. A metal roof in Bradenton with a sealed deck and documented attachment is a different insurance risk from the same roof with none of that on paper.

Common questions

Is an Interlock metal roof approved for Miami-Dade or Broward County?

No. Florida Product Approval NEMO P.E. Evaluated FL7263-R7 is a non-HVHZ approval and does not cover Miami-Dade or Broward, the High-Velocity Hurricane Zone. There is no Miami-Dade NOA for the system, and this site does not serve those two counties. Monroe County is outside the HVHZ but is handled case by case because of its 170 to 180 mph Exposure D design speeds.

Does the warranty's wind figure mean the roof is code-approved for Tampa or Naples?

No. The 120 mph figure is the Guardian warranty's wind commitment when installed to manufacturer specification. Code approval in Tampa, at 150 to 160 mph, or Naples, at about 170, comes from matching an NEMO P.E. Evaluated FL7263-R7 fastening row to the design pressure the engineer calculates for your roof. The warranty and the approval are separate documents.

Will a new metal roof lower my Florida homeowners insurance?

Not automatically. Insurers must offer mitigation discounts under §627.0629, but the credit comes from what the OIR-B1-1802 inspection documents: roof covering, deck attachment, roof-to-wall attachment and secondary water resistance. A metal roof installed with a sealed deck and re-nailing at reroof usually documents well. Ask your carrier what each line is worth.

Warranty terms are summarized; the Guardian Lifetime Limited Material Warranty document governs. Metal Roofing Florida is operated by Interlock Roofing of America, which is not a licensed Florida contractor and does not install roofs; installation is performed by independent, Florida-licensed, manufacturer-certified installers who contract directly with you. Verify any contractor license at myfloridalicense.com.

Ready for answers about your own roof?

Request a quote and a certified Interlock installer is assigned to your project: a visit, and a written proposal under their own license. No obligation.

Interlock® roofing sign: request a quote